When Test IN (3-2-4)is used, the house icon

6. Menu functions

Test IN (3-2-4)

The Test IN (3-2-4)function is used to test how

Follow loop out

Automower finds its way into the charging

 

station.

Follow loop in

 

 

Corridor width

 

Test IN

 

Test OUT

 

3-2-4

When the function is selected, the mower will

 

directly follow the boundary wire or guide wire,

 

depending on which one is found first, in to the

 

charging station. If there is a passage and the

 

mower can not run through it, the Corridor width

 

value is set too high.

 

The adjacent picture shows how an Automower

 

negotiates a passage when a value of 5 is set for

 

the Corridor width, but not when a value of 6 is

 

set.

 

IMPORTANT INFORMATION

 

When Test IN (3-2-4)is used, the house icon

3012-672

 

on the display will come on and the mower

 

will remain in the charging station. Press the

 

Home button to return to operations.

 

Test OUT (3-2-5)

The Test OUT (3-2-5)function is used to try different charge exit settings and to find out how far it is from the charging station to a remote area.

To test the settings for Follow loop out (3-2-1):

State the value 100 % for Proportion for the remote area to be tested. Place Automower in the charging station and select Test OUT (3-2-5). The mower will now leave the charging station directly according to the stated direction and start mowing after the stated distance. Reset the Proportion value when testing is finished.

Follow loop out

Follow loop in

Corridor width

Test IN

Test OUT

3-2-4

Automower from

57

Page 57
Image 57
Husqvarna Automower When Test IN 3-2-4 is used, the house icon, on the display will come on and the mower, Menu functions