Power Requirements

LanProbe Specifications

Power Requirements

Power Module (0950-2546)

Input:100 to 240 VAC, 50/60 Hz, 9.75 Amps

Output:5 V, 2 Amps

Accessory:100 to 240 VAC, 50/60 Hz, 9.5 Amps

Range: 100 VAC to 240 VAC +/- 10%

Environment

 

Operating

Non-Operating

Temperature

0°C to 55°C

-40°C to 70°C

 

(32°F to 131°F)

(-40°F to 158°F)

Relative Humidity

15% to 95%

15% to 90%

(non-condensing)

at 40°C (104°F)

at 65°C (149°F)

Maximum Altitude

4.6 km (15,000 ft)

4.6 km (15,000 ft)

Storage Temperature

-40°C to 70°C (-40°F to 158°F)

Probe Memory Allocation

The memory allocated to each parameter depends on how much memory is installed in LanProbe. The memory parameter values relate to the various items in the RMON or the Agilent private MIBs. These parameters were valid at the time of publication.

Table B-7 on page 103 shows the memory allocated to each parameter for the available LanProbe memory configurations. The memory allocation shown for each table assumes that all of the available memory within the probe is allocated to the identified table.