Figure 3-12: LanProbe Installed in the Rack Support Shelf

Installation

Installing the Probe

8.Attach the support shelf cover to the right LanProbe slot using two 0.312” (7.93 mm) #M3 machine screws, or repeat steps 1 through 9 to install a second LanProbe in the support shelf.

9.Insert the support shelf into the rack (or cabinet) and attach it with four clip-

on sheet metal nuts (use if required) and four 0.55” (14 mm) 10-32 POZIDRIVâ screws. Figure 3-12 shows the completed LanProbe, power module, and support shelf.

10.Attach the power cord to the power module and to a power source. If this is the second LanProbe installed in the support shelf, you can use the optional Female-Male Power Cable (8120-1575) to attach power from one power module to the other.

Figure 3-12: LanProbe Installed in the Rack Support Shelf

36