Set Standby | Timer |
|
|
Input Field |
|
|
|
Major Function Number - | 32h |
| |
Minor Function Number - | ð5h |
| |
Parameter 1 | - | Reserved |
|
Parameter 2 | - | (Bit 15- | 8) Power mode Select |
|
| = ððh - | All mode |
|
| = ð1h - | Manual PM mode (AC) |
|
| = ð2h - | Manual PM mode (Battery) |
|
| = F3h - | High Performance mode |
|
| = F4h - | Auto Pwr Mgmt mode |
|
| (Bit 7- ð) Standby Timer initial value | |
|
| (units: minutes) | |
|
| = ððh - | Disable standby timer |
Parameter 3 | - | Reserved |
|
Parameter 4 | - | Reserved |
|
Parameter 5 | - | Reserved |
|
Output Field |
|
|
|
Return Code | - | Error Status | |
Auxiliary Return Code - | Reserved |
| |
Parameter 1 | - | Reserved |
|
Parameter 2 | - | Reserved |
|
|
| Reserved |
|
Parameter 3 | - | Reserved |
|
Parameter 4 | - | Reserved |
|
Parameter 5 | - | Reserved |
|