![](/images/new-backgrounds/1174422/17442239x1.webp)
Output Protection
A | short | circuit | placed | on | any dc | output (between | outputs | or between | |||||
an | output | and | a dc return) latches all | dc | outputs | into a | shutdown | ||||||
state, | with no | hazardous | condition | to | the | power | supply. |
| |||||
If an overvoltage fault occurs in the | power supply, the power supply | ||||||||||||
latches all dc outputs into a shutdown | state before any | output | |||||||||||
exceeds | 135% | of | the | nominal value | of | the | power | supply. |
|
Voltage Sequencing
When power is turned on, the output voltages reach their operational voltages within 2 seconds.
Power Supply Connector
The following connector is used with the AC Adapter. The total power capacity of this connector must not exceed 4.0 A.
2
1
Refer to Figure
Pin
1
2
Voltage
+7.0 V dc+16to.0 V dc (depending on charging conditions) Ground