10 SET MODE

DScan pause timer

Selects the scan pause time. When receiving signals, the scan pauses according to the scan pause time.

2–20 : Scan pauses for 2–20 sec. on a received signal, and selected in 2 sec. steps. (default: 10 sec.)

HOLD : Scan pauses on a received signal until it disap- pears. Rotate [R-DIAL]to resume manually.

SCAN-PAUSE

SCAN-PAUSE

----------------

----------------

-2SEC

-12SEC

-4SEC

-14SEC

-6SEC

-16SEC

-8SEC

-18SEC

>10SEC

-20SEC

-12SEC

>HOLD

Scan pauses for 10 sec.

Scan pauses until signal

 

disappears

DScan resume timer

Selects scan resume time. Scan resumes after the specified period when the received signal disappears.

0 : Scan resumes immediately when the received signal disappears.

1–5 : Scan pause 1–5 sec. after the received signal disappears. (default: 2 sec.)

HOLD : Scan pauses on the received signal even if it dis- appears. Rotate [R-DIAL]to resume manually.

SCAN-RESUME

SCAN-RESUME

----------------

----------------

-0SEC

-1SEC

-1SEC

-2SEC

>2SEC

-3SEC

-3SEC

-4SEC

-4SEC

-5SEC

-5SEC

>HOLD

Scan resumes after 2 sec.

Scan resumes manually

DScan stop beep

Turns the scan stop beep function ON and OFF.

When the function is activated (“ON” is selected), a long beep will sounds each time when signal is received during scan.

SCAN-STOP-BEEP

SCAN-STOP-BEEP

----------------

----------------

>OFF

-OFF

-ON

>ON

No beep is sound when

A long beep is sound when

receiving a signal

receiving a signal