11 OTHER FUNCTIONS

DCloning error

NOTE: DO NOT push any key on the receiver during

cloning. This will cause a cloning error.

When the display appears as below, a cloning error has oc- curred.

In such a case, the receiver automatically performs ALL RESET while turning power OFF and ON.

CLONE-ERROR

Turn power OFF, then ON

Auto power-off function

IN EXPANDED SET MODE

The IC-R20 can be set to automatically turn OFF after a spec- ified period in which no operation is performed.

BUSY, 120 min., 90 min., 60 min., 30 min. and OFF can be specified. The specified period is retained even when the re- ceiver is turned OFF by the auto power-off function. To cancel the function, select “OFF” in step e below.

qPush [8 SET] for 1 sec. to enter set mode.

wRotate [R-DIAL]to select “AUTO POWER OFF,” then push [8 SET].

• Turn the expanded set mode ON for selection. (p. 49)

ALL-RESET

-DUP TSQL AFC MODE FM ANL

146 010

PSKIP

[R-DIAL]

DUALWATCH

SET

8

***-SET-MODE-***

----------------

-MONITOR >AUTO-POWER-OFF -SCAN-PAUSE

AUTO-POWER-OFF

----------------

-OFF

-30MIN -60MIN -90MIN -120MIN >BUSY

63

eRotate [R-DIAL]to select the desired time or to turn the function OFF, then push [8 SET].

rPush [DUALWATCH] to exit set mode.