KZPCM PCI–to–Dual Channel Ultra SCSI and 10/100MB Ethernet Host Adapter

4.Execute the installation DCL command procedure: $ @ITI_INSTALL

5.The iti_install procedure will automatically:

Move the correct version of the driver to your SYS$LOADABLE_IMAGES directory;

Move the automatic configuraton (ICBM) program to your SYS$SYSTEM directory;

Modify your SYS$USER_CONFIG.DAT file for VMS V7.1-1H2.

When iti_install exits, your adapter(s) are configured, and disks on the adapters are available for use.

5.3Changing the SCSI ID of the Host Adapter (VMS)

At the SRM console (indicated by a >>> or P0> prompt at the system console) storage controllers are identified by the port class prefix PK.

The command >>>show dev pk displays all known disk adapters. When you have identified the location of the adapter you wish to change the ID of, issue the following command:

>>>set pkb0_host_id 6 (this example changes the PKB host adapter ID to 6 from the default of 7)

Verify the change with: >>>show pkb0_host_id

Be sure you do not pick an ID that conflicts with other devices on the bus.

5–8

EK–KZPCM–UG. B01

Page 54
Image 54
Intel EK-KZPCM-UG manual Changing the Scsi ID of the Host Adapter VMS