FAULT SUMMARY

The TT and EEEE fields specifY the fault level and the fault type. The TT bits are interpreted as follows:

TTDescription

00Context Level Faults

01Process Level Faults (group 1)

10Process Level Faults (group 2)

11Processor Level Faults

There are 16 fault types within each of the 4 groups. The encoding column of the tables in the following sections contains the TT and EEEE fields if the type is FF (all other faults).

C-3.<:l3J':OCT LEVEL OPERATOR FAULTS

Faults Common Tb All Operators Or Sub-operations

The following faults can occur anywhere during the execution of an operator or sub-operation (which includes instruction decoding, process dispatching, binding etc.). These faults are not explicitly referenced in the later sections.

FAULT GIDUPS

!TYPE!

ENmDING

Memory Reference Faults =>

 

 

 

Access Rights Fault

AR

 

 

Segment Bound Fault

SB

 

 

Memory Overflow Fault

m

 

 

Bus Error Fault

BE

 

 

Write Rights Fault

I WR

 

 

Invalid Opcode Fault

FF

00

1100

Processor Stopped Fault

FF

00

1101

Object Table Cache Qualification Faults =>

 

 

 

Object Descriptor Type Fault

TS

00010111

Object System Type Fault

TS

00000010

(Access) Segment Altered Faults => => Object Qualification Faults

C-5

Page 146
Image 146