396 Hardware Reference Manual
Intel® IXP2800 Network Processor
Performance Monitor Unit
11.4.6.3 IXP2800 Network Processor MSF Events Target ID(000011) / Design Block #(0110)
63 Hash Cmd_Pipe Full P_CLK single separate Hash Command Pipe Full
64 Hash Push_Data_Pipe
Not_Empty P_CLK single separate Hash Push Data Pipe Not Empty
65 Hash Push_Data_Pipe Full P_CLK single separate Hash Push Data Pipe Full

Table 156. SHaC PMU Event List (Sheet 4 of 4)

Table 157. IXP2800 Network Processor MSF PMU Event List (Sheet 1 of 6)

Event
Number Event Name Clock
Domain
Pulse/
Level Burst Description
0inlet command FIFO
enqueue P_CLK pulse separate
1inlet command FIFO
dequeue P_CLK pulse separate
2 inlet command FIFO full P_CLK level separate
3inlet command FIFO not
empty P_CLK level separate
4read command FIFO
enqueue P_CLK pulse separate
5read command FIFO
dequeue P_CLK pulse separate
6 read command FIFO full P_CLK level separate
7read command FIFO not
empty P_CLK level separate
8write command FIFO
enqueue P_CLK pulse separate
9write command FIFO
dequeue P_CLK pulse separate
10 write command FIFO full P_CLK level separate
11 write command FIFO not
empty P_CLK level separate
12 S_PULL data FIFO 0
enqueue P_CLK pulse separate
13 S_PULL data FIFO 0
dequeue P_CLK pulse separate
14 S_PULL data FIFO 0 full P_CLK level separate
15 S_PULL data FIFO 0 not
empty P_CLK level separate
16 Received Data Training P_CLK level separate
17 Received Calendar Training P_CLK level separate
18 Received Flow Control
Training P_CLK level separate