14-inch Wide Models (FIGURE 19)

FWD WHEELCHAIRS

PROCEDURE 13

14-inch Wide Models (FIGURE 19)

1.Remove the shrouds. Refer toREMOVING/INSTALL- ING SHROUDS in PROCEDURE 10 of this manual.

2.Remove the battery boxes. Refer to REMOVING/IN- STALLINGTHEBATTERYBOXES inPROCEDURE 12 of this manual.

3.Cut the tie wrap that secure the following connections to the wire connector support:

A.The right hand motor and controller connection.

B.The left hand motor and controller connection.

C.Battery wiring harness and controller connection. (BLUE)

4.Disconnect the battery wiring harness (BLUE) and controller connector (BLUE).

5.Remove the two (2) phillips screws and spacers that secure the rear battery connector to the wheelchair frame.

6.Remove the two (2) phillips bolts and locknuts that secure the front battery connector to wheelchair frame.

7.Remove the two (2) phillips screws that secure the wiring harness to the charger cable mounting bracket.

8.Remove the existing wiring harness from wheelchair.

9.Position the rear battery connector of the new wiring harness on the wheelchair frame as shown in FIG- URE 19 and secure with the two (2) phillips screws and spacers.

10.Position the front battery connector on the wheelchair frame as shown in FIGURE 19 and secure with the two (2) phillips bolts and locknuts.

11.Secure the wiring harness to existing charger cable mounting bracket on the seat frame with the two (2) phillips screws.

12.Connect the wiring harness (BLUE) to the controller connector (BLUE).

NOTE: See FIGURE 19 for proper positioning of con- nections on wire connector support.

13.Postion the right hand motor/controller connection and the left hand motor/controller connection side by side on the wire connector support.

14.Postion the battery wiring harness/controller con- nection on top of the right/left hand motor/con- troller connections.

NOTE: When securing the above connections to wire connector support, make sure to wrap tie-wrap around crossbrace and thread through slot in wire connector support.

15.Secure the connections stated in STEPS 13 and 14 to the wire connector support with a tie-wrap.

16.Install the battery boxes. Refer to REMOVING/ INSTALLING THE BATTERY BOXES in PRO- CEDURE 12 of this manual.