Invacare Ranger IIJR REPLACING CLUTCH HANDLES - R2BASIC AND R2JR FIGURE, Fwd Wheelchairs, Spacers

Models: Ranger IISTANDARD

1 84
Download 84 pages 3.62 Kb
Page 60
Image 60
Dust Cover (Not Shown)

PROCEDURE 13

FWD WHEELCHAIRS

F

W

D

W

H

E

E

L

C H A I R S

STEPS 2, 4, 10, 11, 12

Spacers

Dust Cover (Not Shown)

Battery Tray

Hanger

Bracket

Hex Screws Mountingtorque to 60-inch pounds) (STEPS 6, 8)

Footboard

Mounting

Bracket Screws (Apply

LONG Socket Screws (Apply Loctite 242 and

torque to 60-inch pounds) (STEPS 6, 8)

Wheelchair

Frame

SHORT Socket

Screws (Apply

Loctite 242 and

torque to 60-

inch pounds)

(STEPS 6, 8)

Motor/

Gearbox

NOTE: Basic motor/gearbox shown only for clarity. Stan- dard motor gearbox reposition the same way.

NOTE: Basic motor/gearbox - It is not necessary to dis- connect clutch handle from the motor/gearbox.

FRONT MOTOR

MOUNTING POSITION

MIDDLE MOTOR

MOUNTING POSITION

REAR MOTOR

MOUNTING POSITION

FIGURE 20 - REPOSITIONING MOTORS

8.Use Loctite 242 and tighten the motor to the wheel- chair frame securely with the six (6) socket screws. Torque to 60-inch pounds.

9.Repeat STEPS 2-8 for the opposite side of the wheel- chair, if necessary.

10.Line up the mounting hole in the battery tray hanger bracket with the mounting hole in the wheelchair frame.

11.Left side of wheelchair only - Reinstall the front dust cover onto the end of the crossbrace.

12.Perform one (1) of the following:

A.WHEELCHAIR EQUIPPED WITH FLIP-UP RE- MOVABLE FOOTBOARD - Reinstall the hex screws and spacers that secure the battery tray hanger bracket and footboard mounting bracket to the wheelchair frame. Use Loctite 242 and torque to 156-in/lbs.

B.WHEELCHAIR NOT EQUIPPED WITH FLIP-UP REMOVABLE FOOTBOARD - Reinstall the front hex screw that secures the battery tray hanger bracket to the wheelchair frame. Use Loctite 242 and torque to 156-in/lbs.

13.Reinstall the battery boxes. Refer to INSTALLING/RE- MOVING BATTERY BOXES in this procedure of the manual.

REPLACING CLUTCH HANDLES - R2BASIC AND R2JR (FIGURE 21)

1.Remove the battery boxes. Refer to INSTALLING/ REMOVING BATTERY BOXES in this procedure of the manual.

2.Remove the tip from the existing clutch handle.

3.Remove the pin that secures the existing clutch handle to the motor/gearbox.

4.Disconnect the existing clutch handle from the mo- tor/gearbox.

5.Feed existing clutch handle through wheelchair frame.

6.Remove the rubber tip from the new clutch handle.

7.Install the new clutch handle onto the wheelchair.

NOTE: Make sure the new clutch handle is pointing to- wards the outside of the wheelchair.

8.Install the rubber tip onto the new clutch handle.

9.Connect the clutch handle to the motor/gearbox and line up the mounting holes in the clutch handle and motor/gearbox.

10.Insert the pin through the clutch handle and motor/ gearbox as shown in DETAIL "A" in FIGURE 21.

NOTE: Make sure the detent ball on the pin is fully vis- ible.

60

Page 60
Image 60
Invacare Ranger IIJR REPLACING CLUTCH HANDLES - R2BASIC AND R2JR FIGURE, F W D W H E E L C H A I R S, Fwd Wheelchairs