Image 53
Changing Width of Battery Tray (FIGURE 11)

FWD WHEELCHAIRS

PROCEDURE 13

Changing Width of Battery Tray (FIGURE 11)

NOTE: This procedure applies to R2BASIC ANDR2STANDARD

only.

NOTE: This procedure is only necessary when changing the width of the wheelchair.

1.Fold the battery tray. Refer to FOLDING BATTERY TRAY FOR TRANSPORT in this procedure of the manual.

2.Remove the hex bolt and locknut that secure one (1) of the battery tray pins to the battery tray.

3.Refer to FIGURE 11 to determine mounting hole in the battery tray that corresponds to width of the wheelchair.

4.Reposition the battery tray pin to the mounting hole determined in STEP 3.

5.Secure the battery tray pin to the battery tray with the hex bolt and locknut.

6.Repeat STEPS 2-5 for remaining battery tray pin and two battery tray pivots.

Battery Tray Pin

Battery Tray

Hex Bolts

Locknuts

Battery Tray

Pivot

16-inch Wheelchair

18-inch Wheelchair

20-inch Wheelchair

FIGURE 11 - BATTERY TRAY - CHANGING WIDTH OF

BATTERY TRAY

Removing/Installing Battery Tray for R2BASIC

and R2STANDARD.

REMOVING (FIGURE 12).

1.Remove the battery boxes from the wheelchair. Refer toINSTALLING/REMOVINGBATTERYBOXESinthis procedure of the manual.

2.Remove the two (2) hex bolts, four (4) washers and two (2) locknuts that secure the existing battery tray and washers to the battery tray hanger bracket.

3.Remove the existing battery tray from the wheelchair.

INSTALLING (FIGURE 12).

1.Line up mounting holes in the new/existing battery tray with the mounting holes in the battery tray hanger bracket.

2.Position one (1) of the washers between the battery hanger bracket and the new/existing battery tray.

3.Reinstall one (1) of the hex bolts and washers through the new/existing battery tray, washer and battery tray hanger bracket and loosely tighten with a locknut.

4.Repeat STEPS 2-3 for the remaining washers, hex bolt, and locknut.

5.Tighten the two (2) hex bolts and locknuts.

NOTE: Tighten the Two (2) hex bolts and locknuts until the tray stays up by itself. Over tightening the hex bolts and locknuts will make the battery tray difficult to flip up.

6.Reinstall the battery boxes. Refer to INSTALLING/RE- MOVING BATTERY BOXES in this procedure of the manual.

Battery Tray Hanger Bracket

Washers

Hex Bolts

Locknuts

Battery Tray

FIGURE 12 - REMOVING/INSTALLING BATTERY TRAY

FOR R2BASIC AND R2STANDARD .

Removing/Installing Battery Tray R2JR. (FIGURE 13)

REMOVING.

1.Remove the battery boxes from the wheelchair. Refer toINSTALLING/REMOVINGBATTERYBOXESinthis procedure of the manual.

2.Remove the two (2) mounting screws, four (4) wash- ers, and two (2) locknuts that secure the battery tray to the battery tray bracket.

3.Remove the battery tray from the wheelchair.

INSTALLING.

1.Position battery tray inside tab of battery tray bracket.

2.Secure battery tray to battery bracket with the exist- ing two (2) mounting screws, four (4) washers, and two (2) locknuts. Torque mounting screws to 72-inch pounds. See Figure 12 for hardware orientation.