Step 1 Connection/Installation (Continued)
1-4 SERIAL Ports and ALARM Port
Signal names of SERIAL ports and ALARM port located on the back of the unit are shown
below.
[SERIAL 1, 2] Serial ports 1, 2 (Dsub
When viewing from the back of unit
SERIAL 1 port | SERIAL 1 port |
(when set to RS232C) | (when set to RS485) |
SERIAL 2 port |
|
[ALARM] input port for alarm and output port for control (Dsub
| Pin no. | Signal name |
| 1 | OUTPUT 1 |
When viewing from | 2 | OUTPUT 2 |
the back of unit | 3 | OUTPUT 3 |
| 4 | OUTPUT 4 |
| 5 | OUTPUT 5 |
Pin no. | Signal name |
1 | NC |
2 | RXD |
3 | TXD |
4 | NC |
5 | GND |
6 | NC |
7 | NC |
8 | NC |
9 | NC |
Pin no. | Signal name |
1 | NC |
2 | RX – |
3 | TX – |
4 | NC |
5 | GND |
6 | NC |
7 | TX + |
8 | RX + |
9 | NC |
6 | OUTPUT 6 |
7 | OUTPUT 7 |
8 | OUTPUT 8 |
9 | INPUT 1 |
10 | INPUT 2 |
11 | INPUT 3 |
12 | INPUT 4 |
13 | GND |
14 | GND |
15 | GND |
For detailed setup concerning the SERIAL ports,
see “Serial Port Setup screen”, page 40)
Alarm input port
Alarm input port |
|
| Example of sensor |
Unit |
|
| |
DC5V |
|
| VCC |
|
|
| |
R | INPUT |
| R |
| 1~4 | OUT | |
|
|
Output terminal
Output terminal |
| Example of controlled device |
Unit |
| |
|
| DC5V |
R | OUTPUT |
|
| 1~8 | IN |
5V |
|
|
|
GND | GND | GND | GND |
Alarm input equivalent circuit |
|
|
|
<Input conditions> | <Output conditions> | ||
• Signal length setting ( Trigger Duration, page 38) | • Open collector output equivalent | ||
• | Polarity setting ( Trigger, page 38) | • | Polarity setting ( OutputPin 1 ~ 8, page 39) |
• | Connection to 5V power, 10kΩ internally | • | External connection capacity: DC5V, 10mA |
•Current of 10mA or less for input terminal
18