Step 6 Detailed Setup (Continued)
6-7 SERIAL PORT SETUP screen
Serial I/O port related settings can be performed on the SERIAL PORT SETUP screen. Click Serial Port Setup on the left of the Network Code screen to display the SERIAL PORT SETUP screen.
Select the screen
Select from the
Select one for each item
Enter
Select from the
Default values are same for both Serial 1 and Serial 2 ports.
Item | Content | Default value |
|
|
|
Baudrate | Select communication rate. | 19200bps |
| [Variable: 4800bps, 9600bps, 19200bps, 38400bps] |
|
|
|
|
Data Length | Select the data length from | 8 |
| [Variable: 8, 7] |
|
|
|
|
Parity | Select parity bit | None |
| [Variable: Even, Odd, None] |
|
|
|
|
Stop Bit | Select stop bit length. | 1 |
| [Variable: 1, 2] |
|
|
|
|
Comment | This can be used as a memo when viewing this screen | |
| with a Web browser. Entry is optional. (64 characters or |
|
| less) |
|
|
|
|
Timeout (sec) | Set the timeout value when there is no communication. | 0 |
| Number up to 8 digits can be entered. |
|
| Timeout is disabled when 0 is entered. |
|
|
|
|
40