Step 6 Detailed Setup (Continued)
6-5 ALARM SETUP screen (Continued)
|
| Item | Content |
| Default value | |
Input Pin | Select the pin no. of the alarm port to set. | 1 |
| |||
* Following settings are to | [Variable: 1~4] |
|
|
| ||
be performed for each pin. |
|
|
|
| ||
|
|
|
|
|
|
|
| Trigger | Select the polarity of the alarm input signal. | Disabled | |||
|
|
| Input signal is invalid when setting to Disable. |
|
|
|
|
|
| [Variable: Low, High, Disabled] |
|
|
|
|
|
|
|
|
|
|
| Trigger Duration | Set the length of input signal to assume as an alarm. | 100ms | |||
|
|
| [Variable: 50ms, 100ms, 200ms, 300ms, 400ms, 500ms] |
|
|
|
|
|
|
|
|
|
|
| Recording Duration | CF recording duration triggered by alarm is set. Duration |
|
|
| |
|
|
|
| |||
|
|
| before the alarm and duration after the alarm are set. |
|
|
|
|
|
| The maximum time for CF recording triggered by one alarm |
|
|
|
|
|
| is 30 seconds. (Set so that the total time of Before Trigger |
|
|
|
|
|
| and After Trigger is 30 seconds or less.) |
|
|
|
|
|
| 0 cannot be set for both Before Trigger and After Trigger. |
|
|
|
|
|
| * For CF recording, set JPEG in the ENCODE PARAMETERS |
|
|
|
|
|
| screen to “Video In 1” or “Video In 2”. (See page 32) |
|
|
|
|
|
| * Recording will be made before and after for about 1 sec- |
|
|
|
|
|
| ond even when setting to 0s. |
|
|
|
|
|
|
|
|
|
|
|
| Before Trigger | Set the length of time of CF recording before alarm input. | 10s | ||
|
|
| [Variable: 0s, 5s, 10s, 15s, 20s] (Unit: sec) |
|
|
|
|
|
|
|
|
|
|
|
| After Trigger | Set the length of time of CF recording after alarm input. | 20s | ||
|
|
| [Variable: 0s, 5s, 10s, 15s, 20s] (Unit: sec) |
|
|
|
|
|
|
|
|
|
|
| Comment | Input characters must be alphanumerical characters | ||||
|
|
| with a maximum of 64 characters. |
|
|
|
|
|
|
|
|
|
|
Send To |
|
|
|
| ||
|
|
|
|
|
| |
|
| Item | Content |
| Default value | |
|
|
|
|
|
|
|
IP Address | Set the address to send the alarm information. |
| Blank | |||
|
|
| Up to 2 destination addresses can be specified. |
|
|
|
|
|
|
|
|
|
|
Port | Set the port number to send the alarm information. | 10000 | ||||
|
|
| The maximum value is 65535. |
|
|
|
|
|
|
|
|
|
|
Data | Set the sending data. Up to 64 characters can be entered. |
| data | |||
|
|
|
|
|
|
|
Protocol | Set the transmission protocol: |
| TCP | |||
|
|
| TCP: Alarm information is sent by TCP. |
|
|
|
|
|
| Character string entered in Data will be sent to the |
|
|
|
|
|
| set port no. |
|
|
|
|
|
| Some custom application software may be required |
|
|
|
|
|
| to receive the alarm information by TCP. |
|
|
|
|
|
| API: Select when sending the alarm information to |
|
|
|
|
|
| monitor side |
|
|
|
|
|
| Port is set to |
|
|
|
|
|
| “Disable”. |
|
|
|
|
|
|
|
|
|
|
* When clicking | with Comment and Data left blank, an underscore (_) will be inserted automatically. |
38 |
|