Settings by Telnet of the PC

Connection

Connect the unit and PC using a network.

Ping command is available to test connection via network. <Checking method>

Example: If the IP address of the unit is 10.0.0.1 (factory set IP address)

1.Start command prompt on the PC.

2.Type “ping 10.0.0.1”.

3.If setting and connection are correct, responses such as shown below will be displayed. “Reply from 10.0.0.1: bytes: 32 time tieme<10ms TTL=64”

If there is some problem, the following timeout error will be displayed. “Request timed out.”

Launching Telnet

Start telnet on PC

Example: When the IP address of the unit is 10.0.0.1 (factory set IP address)

1.Start command prompt.

2.Type “telnet 10.0.0.1”.

3.Enter “nc40api” as the user name and “dm-nc40” as the password.

Memo

When displayed lines in the telnet window are not enough, increase the buffer size in the settings of the Telnet software.

Commands

Commands are the same for the terminal software. ( i See page 54)

Memo

When restarting from Telnet, the Telnet connection will be disconnected.

To continue operation from Telnet, perform the connection procedure again after the unit reboot.

Exiting Tenet

Enter “exit”.

Memo

If Telnet cannot be exited properly due to network or PC problems, reconnection of Tenet will fail since the unit keeps previous Telnet connection. Reconnection will be possible in 10 minutes by timeout of previous telnet connection.

Telnet can be disconnected by rebooting the unit.