5: Commands and Levels

 

 

 

start character

 

is received on the line.

default connect mode

Restores the default connect mode as "disable".

default host mode

Connects to the first host in the list that accepts the con-

 

nection.

default local port

Uses a random port number as the local port for establish-

 

ing tunneling

 

connections to other devices.

default reconnect time

Restores the default reconnect time value for connect

 

mode tunneling.

default start character

Defaults the connect mode start character.

email connect <number>

Sets an email profile to use to send an email alert upon

 

establishing

 

a connect mode tunnel.

 

<number> = the number of the email profile to use.

email disconnect <number>

Sets an email profile to use to send an email alert upon

 

closing

 

a connect mode tunnel.

 

<number> = the number of the email profile to use.

exit

Returns to the tunnel level.

flush serial disable

Characters already in the serial data buffer are retained

 

upon establishing

 

a connect mode tunneling connection.

flush serial enable

Flushes the serial data buffer upon establishing a connect

 

mode tunneling

 

connection.

flush start character disable

Enables forwarding of the connect start character into the

 

network.

flush start character enable

Disables forwarding of the connect start character into the

 

network.

host <instance>

Enters the next lower level.

 

Specify the instance for the next lower level.

host mode sequential

Connects to the first host in the list that accepts the con-

 

nection.

host mode simultaneous

Selects simultaneous connections to all hosts on the host

 

list.

kill connection

Disconnects the active connect mode tunneling connec-

 

tion or connections.

local port <number>

Sets a specific port for use as the local port.

 

<number> = the number of the port to use.

no email connect

Discontinues sending email alerts upon establishing a

 

connect mode tunnel.

no email disconnect

Discontinues sending email alerts upon closing a connect

 

mode tunnel.

promote host <number>

Promotes the identified host, exchanging it place with the

 

host above it,

 

to adjust the order of the defined hosts.

reconnect time <milliseconds>

Sets the reconnect time value for tunneling connections

 

established by the

 

device in milliseconds.

 

<milliseconds> = timeout in milliseconds.

show

Displays the current configuration.

show history

Displays the last 20 commands entered during the current

 

CLI session.

show status

Displays tunnel connect status.

PremierWave XN Command Reference

55

Page 55
Image 55
Lantronix 900-607 manual Host instance