| 5: Commands and Levels |
|
|
show history | Displays the last 20 commands entered during the current |
| CLI session. |
show line | Displays the current configuration. |
show statistics | Shows the line statistics. |
state disable | Disables the line so data cannot be sent/received. |
state enable | Enables the line so data can be sent/received. |
stop bits 1 | Uses one stop bit after data on the line. |
stop bits 2 | Uses two stop bits after data on the line. |
terminal <line> | Enters the |
| <line> = number of the terminal line (serial port) to be con- |
| figured. |
terminal network | Enters the |
termination disable | Refrains from terminating the line. |
termination enable | Enables 120 ohm line termination in RS485 |
| mode. |
threshold <bytes> | Sets the threshold in bytes. After this many bytes are re- |
| ceived, they are |
| forwarded without delay. |
tunnel <line> | Enters the tunnel level. |
| <line> = number of the tunnel line (serial port) to be confi- |
| gured. |
write | Stores the current configuration in permanent memory. |
xoff char <control> | Sets the xoff character for use with software flow control |
| on this line. |
| The character may be input as text, control, decimal, or |
| hex. |
| A control character has the form <control>C. |
| A decimal value character has the form \99. |
| A hex value character has the form 0xFF. |
xon char <control> | Sets the xon character for use with software flow control |
| on this line. |
| The character may be input as text, control, decimal, or |
| hex. |
| A control character has the form <control>C. |
| A decimal value character has the form \99. |
| A hex value character has the form 0xFF. |
link |
|
active channel scan time <milliseconds> | Sets the active channel scan time in milliseconds. |
apply wlan | Try out WLAN settings without saving them to Flash. |
| If the settings do not work, when you reboot the device, |
| it will still have the original settings. |
cancel wps | Cancels |
choice <instance> | Enters the next lower level. |
| Specify the instance for the next lower level. |
clrscrn | Clears the screen. |
debugging level debug | Sets the WLAN debugging level to Debug. |
debugging level dump | Sets the WLAN debugging level to Dump, the most ver- |
| bose option. |
debugging level error | Sets the WLAN debugging level to Error, which shows |
| only errors. |
debugging level info | Sets the WLAN debugging level to Info. |
debugging level warning | Sets the WLAN debugging level to Warning. |
default active channel scan time | Restores the default active channel scan time. |
default debugging level | Sets the WLAN debugging level to its default value, Info. |
PremierWave XN Command Reference | 150 |