5: Commands and Levels
PremierWave XN Command Reference 146
no hostname
Clears the host name.
no ip address
Clears the IP address.
no primary dns
Clears the name of the primary DNS server.
no secondary dns
Clears the name of the secondary DNS server.
primary dns <IP address>
Sets the IP address of the primary DNS server.
secondary dns <IP address>
Sets the IP address of the secondary DNS server.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current
CLI session.
show status
Show interface status
state disable
Disables the interface.
state enable
Enables the interface.
write
Stores the current configuration in permanent memory.
ip (config-ip) level commands
clrscrn
Clears the screen.
default ip time to live
Restores the default IP time to live.
default multicast time to live
Restores the default IP multicast time to live, which is one
hop.
exit
Exits to the configuration level.
ip time to live <hops> Sets the IP time to live, known by SNMP as "ipDe-
faultTTL".
<hops> = number of hops that a typical IP packet is al-
lowed to live.
multicast time to live <hops>
Sets the IP multicast time to live.
<hops> = number of hops that a multicast IP packet is
allowed to live.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current
CLI session.
write
Stores the current configuration in permanent memory.
line 1 (line:1) level commands
auto show statistics
Continuously displays line statistics.
baud rate
<bits per second>
Sets the line speed.
<bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600, 19200,
and so on.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command mode.
command mode echo serial string disable Disables user-defined serial boot string to be echoed in
the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed in the
CLI.
command mode serial string Enables user to enter a custom
string at boot time to enter
command mode.
command mode serial string <string>
Sets a string that can be entered at boot time to enter
command mode.
<string> = text with possible binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
Within {} specify decimal milliseconds time delay.
command mode signon message <string>
Sets a sign-on message that is sent from the serial port
when the
device boots and when the line is in command mode.