Symptom

 

Action

 

 

A newly installed non-hot-swap hard disk drive is not

1. Make sure that:

recognized.

 

• The signal cable and connector are not damaged.

 

 

 

 

• The non-hot-swap hard disk drive is securely

 

 

connected to the correct SATA connector on the

 

 

system board and the SATA connector is enabled

 

 

in the Setup Utility program. See “Using the Setup

 

 

Utility program” on page 21.

 

 

• All cables and jumpers (if any) are installed

 

 

correctly.

 

2.

If you have any diagnostic programs, run the

 

 

diagnostic programs to test the hard disk drive.

 

3.

Reinstall the non-hot-swap hard disk drive and

 

 

reconnect cables.

 

4.

Replace the signal cable for the non-hot-swap hard

 

 

disk drive.

 

5.

Replace the non-hot-swap hard disk drive.

 

 

Multiple hard disk drives fail.

1. If you have any diagnostic programs, run the

 

 

diagnostic programs to test the hard disk drives.

 

2.

Make sure that the cable connection is correct.

 

3.

Reconnect the power cable.

 

4.

Reconnect the signal cable.

 

5.

Replace the affected signal cable.

 

 

 

Memory module problems

Follow the suggested actions for the corresponding symptom in the order in which they are listed until the problem is solved. If none of these actions solve the problem, see “Troubleshooting procedure” on page 83 for the subsequent steps you should check after using the information in this topic. If the problem cannot be solved by yourself, seek technical assistance. See Chapter 8 “Getting information, help, and service” on page 89.

Notes:

1.If you are instructed to remove, install, or replace any CRUs, refer to the related procedure in “Installing, removing, or replacing hardware” on page 40.

2.If an action step is preceded by “(Trained service technician only),” this action step is reserved for a trained service technician and must be performed only by a trained service technician.

Symptom

Action

 

 

The amount of system memory that is displayed is less

1. Make sure that:

than the total capacity of the installed physical memory

• All memory modules are the correct type

modules and you suspect a memory module problem.

supported by the server. See “Features” on page

 

 

7.

 

• You follow the memory module installation rules.

 

See “Memory module installation rules” on page

 

41.

 

• All memory modules are seated correctly and

 

securely.

 

• The system firmware is up-to-date.

 

 

86ThinkServer TS140 User Guide

Page 98
Image 98
Lenovo TS140 manual Memory module problems