FRU | Action |
|
|
Model E310 | Disconnect the cables from CN2 and |
Engine/LVPS Board | CN5 and leave the cables connected |
Power Switch | to the power switch attached. With |
| the printer positioned on its left side |
| and the engine/LVPS board |
| positioned on a flat surface, turn the |
| power switch on and check the AC |
| line voltage at connector CN201. If |
| no voltage is present, replace the |
| power switch. If line voltage is |
| present, measure the voltages at |
| connectors CN2 and CN5. Go to |
| the“Engine/LVPS Board (model |
| E310)” on page |
| correct voltage measurements. |
| Replace the engine/LVPS board if |
| any of the voltage measurements |
| are incorrect. |
|
|
Model E310 | Check the continuity of the LVPS to |
LVPS to Interconnect Board | interconnect board cable. Replace |
Cable | the cable if it does not measure |
| continuity. |
|
|
Model E310 | Reconnect the LVPS to the |
Interconnect Board | interconnect board cable. Go to |
| “Interconnect Board (model E310)” |
| on page |
| on the following connectors on the |
| interconnect board: |
| CN401/CN402/CN403/CN404/ |
| CN405/CN407/CN408 |
| If any of the measured voltages are |
| incorrect, replace the interconnect |
| board. |
|
|
Model E312 | Place the printer on its rear side. |
Power Switch | Position the LVPS board on a flat |
| surface with all the cables |
| connected. Turn the printer power |
| switch to the on position. Check the |
| AC line voltage at power switch |
| connector CN501. If no voltage is |
| present, replace the power switch |
|
|
Diagnostic Information