Operator Panel Service Check
Inspect the operator panel cable for damage. Make sure the cable is plugged in securely.
Run POST and check each LED for proper operation.
FRU | Action |
|
|
Models E310 & E312 | If more than one LED does not turn |
Operator Panel | on or an individual LED stays on |
Operator Panel Cable | solid during POST, check the |
| operator panel cable for continuity. |
| Replace if defective. If the cable |
| measures continuity, replace the |
| operator panel. |
|
|
Models E310 & E312 | If all LEDs are dim and operate |
Operator Panel | erratically during POST or all LEDs |
Operator Panel Cable | come on and stay on solid during |
Controller Board | POST, replace the following FRUs |
| one at a time in the order shown: |
| Controller Board |
| Operator Panel |
| Operator Panel Cable |
| If none of the LEDs come on, make |
| sure the cable is properly connected |
| to the operator panel and the |
| controller board. Disconnect the |
| cable and check it for continuity. |
| Replace if necessary. If the cable |
| measures continuity, measure the |
| following voltages with the printer on |
| at idle: |
| |
| |
| |
| |
| |
| If these voltages are not correct, |
| replace the controller board. If these |
| voltages are correct, replace the |
| operator panel. |
|
|
Diagnostic Information