Lexmark E310 manual Operator Panel Service Check, 4044-XXX, Diagnostic Information, Action

Models: 4044-XXX E310

1 154
Download 154 pages 7.24 Kb
Page 45
Image 45

4044-XXX

Operator Panel Service Check

Inspect the operator panel cable for damage. Make sure the cable is plugged in securely.

Run POST and check each LED for proper operation.

FRU

Action

 

 

Models E310 & E312

If more than one LED does not turn

Operator Panel

on or an individual LED stays on

Operator Panel Cable

solid during POST, check the

 

operator panel cable for continuity.

 

Replace if defective. If the cable

 

measures continuity, replace the

 

operator panel.

 

 

Models E310 & E312

If all LEDs are dim and operate

Operator Panel

erratically during POST or all LEDs

Operator Panel Cable

come on and stay on solid during

Controller Board

POST, replace the following FRUs

 

one at a time in the order shown:

 

Controller Board

 

Operator Panel

 

Operator Panel Cable

 

If none of the LEDs come on, make

 

sure the cable is properly connected

 

to the operator panel and the

 

controller board. Disconnect the

 

cable and check it for continuity.

 

Replace if necessary. If the cable

 

measures continuity, measure the

 

following voltages with the printer on

 

at idle:

 

U5-1: Ground

 

U5-2: +5 V dc

 

U5-3: +5 V dc

 

U5-5: +5 V dc

 

U5-6: Ground

 

If these voltages are not correct,

 

replace the controller board. If these

 

voltages are correct, replace the

 

operator panel.

 

 

Diagnostic Information 2-23

Page 45
Image 45
Lexmark E310 manual Operator Panel Service Check, 4044-XXX, Run POST and check each LED for proper operation, Action