4044-XXX
The fuser lamp does not light
FRU | Action |
|
|
Model E310 | Turn the printer off and disconnect |
Fuser Lamp | the fuser lamp wires from the fuser. |
Lamp Cable | Check for continuity across the fuser |
Thermistor | lamp wire contacts. If there is |
LVPS | continuity, go to step 1: Continuity. |
| If there is no continuity, go to |
| step 2: No Continuity. |
| Step 1: Continuity |
| Measure the voltage at connector |
| CN202 on the LVPS. It should match |
| the line voltage. If it does not, |
| replace the LVPS. If line voltage is |
| present, check the fuser lamp cable |
| for continuity. Replace if |
| defective.Make sure the fuser |
| thermistor is correctly connected to |
| CN1 on the LVPS. If the problem |
| persists, disconnect the thermistor |
| cable from CN1 on the LVPS board |
| and measure the voltage between |
| |
| measures approximately 3.9 V dc. If |
| the voltage is incorrect, replace the |
| LVPS. If correct, replace the |
| thermistor. |
| Step 2: No Continuity |
| Check the thermal fuse for continuity. |
| If incorrect, replace the thermal fuse. |
| If correct, replace the lamp. |
|
|
Diagnostic Information