Operator Panel Button Service Check
FRU | Action |
|
|
Models E310 & E312 | Disconnect the operator panel from |
Operator Panel | the operator panel cable. Check the |
Operator Panel Cable | continuity between |
| on the operator panel as you press |
| the operator panel button. As the |
| button is pressed, continuity is |
| present. Replace the operator panel |
| if continuity is not present. If |
| continuity is present, replace the |
| operator panel cable. |
|
|
Paper Feed Service Check
Paper Jam error indication during POST
FRU | Action |
|
|
Models E310 & E312 | If the exit sensor flag is not resting |
Exit Sensor Flag | within the paper exit sensor during |
| POST, the printer displays a paper |
| jam message. Make sure the flag is |
| operating freely and correctly |
| installed. |
|
|
Models E310 & E312 | Make sure the input paperfeed |
Input Paper Feed Sensor | sensor is working properly. A stuck |
| or incorrectly installed sensor |
| causes this error. |
|
|