4044-XXX
Hot Fuser Service Check
FRU | Action |
|
|
Model E310 | Disconnect the thermistor cable from |
Fuser Thermistor | the LVPS. Measure the resistance |
| across |
| thermistor cable. Replace the |
| thermistor if the resistance is lower |
| than 1k ohm or shorted. |
|
|
Model E312 | Disconnect the thermistor cable from |
Fuser Thermistor | the engine board. Measure the |
| resistance across |
| |
| Replace the thermistor if the |
| resistance is lower than 1k ohm or |
| shorted. |
|
|
Models E310 & E312 | Make sure the correct voltage fuser |
Fuser Lamp | lamp is installed. Replace if |
| necessary. |
|
|
Main Motor Service Check
FRU | Action |
|
|
Model E310 | Check the interconnect board for the |
Interconnect Board | following voltages: |
Main Motor |
|
Main Motor Cable | |
| |
| If these voltages are not correct, |
| replace the interconnect board. If |
| these voltages are correct, check the |
| main motor cable for continuity. If |
| continuity exists on each wire, |
| replace the main motor. If continuity |
| does not exist on one or more of the |
| wires, replace the cable. |
|
|
Diagnostic Information