Black page
Note: Incorrect laser exposure or incorrect charging of the photoconductor causes an all black page.
FRU | Action |
|
|
Models E310 & E312 | Check the contacts for |
HVPS Contacts | contamination and correct |
| installation. Replace as necessary. |
|
|
Model E310 | Make sure the HVPS to engine/ |
Engine/LVPS Board | LVPS cable is correctly installed. |
HVPS Cable | Disconnect the cable and measure |
HVPS | the signals on CN2 of the engine/ |
| LVPS board. Go to “Engine/LVPS |
| Board (model E310)” on page |
| and check the voltage |
| measurements. If the voltages are |
| not correct, replace the engine/LVPS |
| board. If the voltages are correct, |
| check the HVPS to engine/LVPS |
| cable for continuity. If the cable does |
| not measure continuity, replace the |
| cable. If the cable measures |
| continuity, replace the HVPS. |
|
|
Model E312 | Make sure the HVPS to engine |
Engine Board | board cable is correctly installed. |
HVPS Cable | Disconnect the cable and measure |
HVPS | the signals on CN11 of the engine |
| board. Go to the “Engine Board |
| (model E312)” on page |
| the voltage measurements. If the |
| voltages are not correct, replace the |
| engine board. If the voltages are |
| correct, check the HVPS to engine |
| board cable for continuity. If the |
| cable does not measure continuity, |
| replace the cable. If the cable |
| measures continuity, replace the |
| HVPS. |
|
|