Black page

Note: Incorrect laser exposure or incorrect charging of the photoconductor causes an all black page.

FRU

Action

 

 

Models E310 & E312

Check the contacts for

HVPS Contacts

contamination and correct

 

installation. Replace as necessary.

 

 

Model E310

Make sure the HVPS to engine/

Engine/LVPS Board

LVPS cable is correctly installed.

HVPS Cable

Disconnect the cable and measure

HVPS

the signals on CN2 of the engine/

 

LVPS board. Go to “Engine/LVPS

 

Board (model E310)” on page 5-4

 

and check the voltage

 

measurements. If the voltages are

 

not correct, replace the engine/LVPS

 

board. If the voltages are correct,

 

check the HVPS to engine/LVPS

 

cable for continuity. If the cable does

 

not measure continuity, replace the

 

cable. If the cable measures

 

continuity, replace the HVPS.

 

 

Model E312

Make sure the HVPS to engine

Engine Board

board cable is correctly installed.

HVPS Cable

Disconnect the cable and measure

HVPS

the signals on CN11 of the engine

 

board. Go to the “Engine Board

 

(model E312)” on page -9. Check

 

the voltage measurements. If the

 

voltages are not correct, replace the

 

engine board. If the voltages are

 

correct, check the HVPS to engine

 

board cable for continuity. If the

 

cable does not measure continuity,

 

replace the cable. If the cable

 

measures continuity, replace the

 

HVPS.

 

 

Diagnostic Information 2-29