Lexmark 4044-XXX, E310 manual Dead Machine Service Check

Models: 4044-XXX E310

1 154
Download 154 pages 7.24 Kb
Page 36
Image 36

4044-XXX

FRU

Action

 

 

Model E312

Measure the voltages at CN2 of the

HVPS

HVPS. CN2-3 measures +5 V dc

 

and CN2-4 measures +24 V dc. If

 

the correct voltage is present, check

 

the continuity between the following

 

connector locations:

 

CN2-3 - CN1-17

 

CN2-3 - CN1-19

 

CN2-4 - CN1-2

 

CN2-4 - CN1-4

 

If any location does not measure

 

continuity, replace the HVPS.

 

 

Model E312

Replace the cable if it does not

HVPS to Engine Board Cable

measure continuity.

 

 

E312

Go to the “Engine Board (model

Engine Board

E312)” on page -9. Measure the

 

voltages on CN11. If any voltages

 

are incorrect, replace the engine

 

board.

 

 

Dead Machine Service Check

Note: Check the AC line voltage. The voltage should be within the following limits:

100 V ac - 127 V ac for the low voltage model printer

200 V ac - 240 V ac for the high voltage model printer

FRU

Action

 

 

Model E310 & E312

Check the fuse on the LVPS for

LVPS Fuse

continuity. Replace with the

 

appropriate fuse if blown. If a fuse

 

blows again after being replaced,

 

install a new fuse and go to “Engine/

 

LVPS Board (model E310)” on

 

page 5-4and check the engine/

 

LVPS board output.

 

 

2-14Service Manual

Page 36
Image 36
Lexmark 4044-XXX, E310 manual Dead Machine Service Check