FRU | Action |
|
|
Model E312 | Measure the voltages at CN2 of the |
HVPS | HVPS. |
| and |
| the correct voltage is present, check |
| the continuity between the following |
| connector locations: |
| |
| |
| |
| |
| If any location does not measure |
| continuity, replace the HVPS. |
|
|
Model E312 | Replace the cable if it does not |
HVPS to Engine Board Cable | measure continuity. |
|
|
E312 | Go to the “Engine Board (model |
Engine Board | E312)” on page |
| voltages on CN11. If any voltages |
| are incorrect, replace the engine |
| board. |
|
|
Dead Machine Service Check
Note: Check the AC line voltage. The voltage should be within the following limits:
100 V ac - 127 V ac for the low voltage model printer
200 V ac - 240 V ac for the high voltage model printer
FRU | Action |
|
|
Model E310 & E312 | Check the fuse on the LVPS for |
LVPS Fuse | continuity. Replace with the |
| appropriate fuse if blown. If a fuse |
| blows again after being replaced, |
| install a new fuse and go to “Engine/ |
| LVPS Board (model E310)” on |
| page |
| LVPS board output. |
|
|