FRU | Action |
|
|
Model E312 | Turn the printer off and disconnect |
Fuser Lamp | the fuser lamp wires from the fuser. |
Lamp Cable | Check for continuity across the fuser |
Thermistor | lamp wire contacts. If there is |
LVPS | continuity, go to step 1: Continuity. |
| If there is no continuity, go to |
| step 2: No Continuity. |
| Step 1: Continuity |
| Measure the voltage at connector |
| CN502 on the LVPS. It should match |
| the line voltage. If it does not, |
| replace the LVPS. If line voltage is |
| present, check the fuser lamp cable |
| for continuity. Replace if |
| defective.Make sure the fuser |
| thermistor is correctly connected to |
| CN10 on the engine board. If the |
| problem persists, disconnect the |
| thermistor cable from CN1o on the |
| engine board and measure the |
| voltage between |
| ground. The voltage measures |
| approximately 3.9 V dc. If the voltage |
| is incorrect, replace the engine |
| board. If correct, replace the |
| thermistor. |
| Step 2: No Continuity |
| Check the thermal fuse for continuity. |
| If incorrect, replace the thermal fuse. |
| If correct, replace the lamp. |
|
|