4044-XXX

FRU

Action

 

 

Model E312

Turn the printer off and disconnect

Fuser Lamp

the fuser lamp wires from the fuser.

Lamp Cable

Check for continuity across the fuser

Thermistor

lamp wire contacts. If there is

LVPS

continuity, go to step 1: Continuity.

 

If there is no continuity, go to

 

step 2: No Continuity.

 

Step 1: Continuity

 

Measure the voltage at connector

 

CN502 on the LVPS. It should match

 

the line voltage. If it does not,

 

replace the LVPS. If line voltage is

 

present, check the fuser lamp cable

 

for continuity. Replace if

 

defective.Make sure the fuser

 

thermistor is correctly connected to

 

CN10 on the engine board. If the

 

problem persists, disconnect the

 

thermistor cable from CN1o on the

 

engine board and measure the

 

voltage between CN10-1 and

 

ground. The voltage measures

 

approximately 3.9 V dc. If the voltage

 

is incorrect, replace the engine

 

board. If correct, replace the

 

thermistor.

 

Step 2: No Continuity

 

Check the thermal fuse for continuity.

 

If incorrect, replace the thermal fuse.

 

If correct, replace the lamp.

 

 

2-20Service Manual