ENGINE OPERATION

Break-in Period

 

Starting/Shutdown Instructions

It is normal for any engine to use larger quantities of oil

 

until break-in is accomplished. Check the oil level

Be sure all Pre-Operation Engine Service has been

twice a day during the break-in period (about 50 run-

ning hours). Change the oil after the first 5 hours of

performed. Also, Read owners manual before starting

operation. See the Engine Instruction Manual for fur-

for the first time. (See INSTALLATION section)

ther details.

 

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Remove all loads connected to the AC power recepta- cles. Before starting, first open the fuel shutoff valve.

Always pull the choke control out when starting the engine; cold, warm or hot.

Turn the engine switch to the “Start” position and crank the engine until it starts, slowly return the choke control to the full “in” position (choke open), and turn

the switch to the Auto Idle ( / ) position. Do not turn the switch to the “start” position while the engine is running because this will cause damage to the ring gear and/or starter motor.

Stopping the Engine

Remove all welding and auxiliary power loads and allow engine to run for a few minutes to cool the engine.

Stop the engine by placing the engine switch in the

“Off” ( ) position.

WARNING

Close the fuel valve when the machine is transported to prevent fuel leakage from the carburetor.

------------------------------------------------------------------------

CAUTION

IN ORDER TO ACCOMPLISH THIS BREAK-IN, THE UNIT SHOULD BE SUBJECTED TO MODERATE LOADS, WITHIN THE RATING OF THE MACHINE. AVOID LONG IDLE RUNNING PERIODS. REMOVE LOADS AND ALLOW ENGINE TO COOL SEVERAL MINUTES AT LOW IDLE BEFORE SHUTDOWN.

-----------------------------------------------------------------------

Low Oil Sensing

This engine has a built in sensor which responds to low oil level (not pressure). When activated, the system will shut the engine down. The engine will not restart until sufficient oil is added. Check oil level frequently and add oil as required to the full mark on the dipstick.

DO NOT OVERFILL.

Typical Fuel Consumption

 

KOHLER CS 12.75 HP

 

 

NO LOAD.

.20 GALLONS/HOUR

2250 R.P.M

.75 ( LITERS/HOUR)

 

 

NO LOAD

.40 GALLONS/HOUR

3750 R.P.M.

1.51 ( LITERS/HOUR)

 

 

DC CC WELD OUTPUT

.73 GALLONS/HOUR

100 AMPS, 25 VOLTS

2.77 ( LITERS/HOUR)

 

 

AUXILIARY POWER

.99 GALLONS/HOUR

5200 KVA

3.74 ( LITERS/HOUR)

 

 