D-3

MAINTENANCE

D-3

 

Return to Master TOC

Return to Master TOC

SAFETY PRECAUTIONS

WARNING

Have qualified personnel do all maintenance and troubleshooting work.

Turn the engine off before working inside the machine.

Remove guards only when necessary to perform maintenance and replace them when the mainte- nance requiring their removal is complete.

If guards are missing from the machine, get replace- ments from a Lincoln Distributor. See the EXPLOD- ED VIEW AND PARTS LIST at the back of this man- ual.

------------------------------------------------------------------------

Read the Safety Precautions in the front of this manu- al and in the Kohler Operating and Maintenance Instructions manual before working on the OUT- BACK®185 Keep all equipment safety guards, covers, and devices in position and in good repair. Keep your hands, hair, clothing, and tools away from the recoil housing, fans, and all other moving parts when start- ing, operating, or repairing this machine.

OIL: Check the oil level after every 5 hours of operation or daily. BE SURE TO MAINTAIN THE OIL LEVEL.

Change the oil the first time after 20 hours of opera- tion. Then, under normal operating conditions, change the oil after every 100 hours or once a year, whichev- er occurs first. If the engine is operated under heavy load or in high ambient temperatures, change the oil every 50 hours.

Drain the oil from the drain plug located on either side of the engine bottom, as shown in Figure D.1. Refill through the oil fill plug until the oil reaches the full mark on the dip stick. See Engine Owner’s manual for spe- cific oil recommendations.

FIGURE D.1 - OIL DRAIN AND

REFILL LOCATION

Return to Section TOC

Return to Section TOC

ROUTINE AND PERIODIC MAINTENANCE

Do not screw in

FILL to FULL mark on

dipstick to check oil

dipstick - recheck

Return to Section TOC

Return to Master TOC

ENGINE MAINTENANCE

CAUTION

To prevent the engine from accidentally starting, dis- connect the spark plug lead before servicing the engine.

------------------------------------------------------------------------

Tighten dipstick firmly before starting

12 mm

HEX

Drain

plug

OIL DRAIN

PLUG

Oil drain

Return to Section TOC

Return to Master TOC

See the Kohler Owner’s manual for a summary of maintenance intervals for the engine. Follow either the hourly or the calendar intervals, whichever come first. More frequent service may be required, depending on your specific application and operating conditions. The Kohler Owner’s manual shows engine maintenance replacement parts and numbers.

FUEL: At the end of each day’s use, refill the fuel tank to minimize moisture conden- sation and dirt contamination in the fuel line.

AIR CLEANER: With normal operating conditions, the maintenance schedule for cleaning and re-oiling the foam pre-filter is every 50 hours and replacement of the air cleaner filter element every 100 hours.

More frequent servicing is required with dusty operat- ing conditions. Refer to the maintenance section of the Engine Owner’s Manual for more information.

OUTBACK® 185