PLUGS AND HAND HELD EQUIPMENT

For further protection against electric shock, any elec- trical equipment connected to the generator recepta- cles must use a three-blade, grounded type plug or an Underwriter’s Laboratories (UL) approved double insu- lated tool with a two blade plug.

WARNING

Never operate this machine with damaged or defective cords. All electrical equipment must be in safe operating condition.

------------------------------------------------------------------------

AUXILIARY POWER RECEPTACLES

The control panel of the OUTBACK® 185 features three auxiliary power receptacles:

Two 20 amp,120 volt duplex (double outlet) receptacle.

A 50 amp, 240 volt single outlet receptacle.

See Figure A.1

Through these receptacles the machine can supply up to 5700 watts surge or 5200 watts continuous of single- phase 60 Hertz AC power. The machine output volt- ages meet UL standards and fall within ± 10% of the rated voltage.

PREMISES WIRING

The OUTBACK® 185 is not recommended for premis- es wiring. The OUTBACK® 185 does not have a com- bined 120/240 volt receptacle and cannot be connect- ed to a premises as described in other Lincoln litera- ture.

The OUTBACK® 185 is intended only for backup, intermittent use power. Certain electrical devices can- not be powered by the OUTBACK® 185. Refer to Table A.2 for these devices.

CIRCUIT BREAKERS

Auxiliary power is protected by circuit breakers. When the machine is operated in high temperature environ- ments, the breakers may tend to trip at lower loads than normally.

CAUTION

NEVER BYPASS THE CIRCUIT BREAKERS. WITH- OUT OVERLOAD PROTECTION, THE UNIT COULD OVERHEAT AND/OR CAUSE DAMAGE TO THE EQUIPMENT BEING USED.

------------------------------------------------------------------------