Lincoln Electric SVM 117-A service manual Active SCR Rectifier Assembly Test, Test Description

Models: SVM 117-A

1 102
Download 102 pages 32.42 Kb
Page 69
Image 69

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-16

TROUBLESHOOTING & REPAIR

F-16

 

 

ACTIVE SCR RECTIFIER ASSEMBLY TEST

WARNING

Service and repair should be performed only by Lincoln Electric factory trained per- sonnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and pre- cautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed.

Call (216) 383-2531 or (800) 833-9353 (WELD).

_____________________________________________________________

TEST DESCRIPTION

The Active SCR Test will determine if the device is able to be gated ON and conduct current from anode to cathode.

MATERIALS NEEDED

An SCR Tester as specified in this procedure.

Wire-Matic 250 wiring diagrams (See Electrical Diagrams Section of this Manual).

SCR Heat Sink Assembly Drawings.

WIRE-MATIC 250

Page 69
Image 69
Lincoln Electric SVM 117-A service manual Active SCR Rectifier Assembly Test, Test Description