Lincoln Electric SVM 117-A service manual Perform the Output Rectifier

Models: SVM 117-A

1 102
Download 102 pages 32.42 Kb
Page 62
Image 62

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-9

TROUBLESHOOTING & REPAIR

F-9

 

 

 

TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENTS(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

WELDING PROBLEMS

 

 

 

 

 

 

 

 

The welding arc is variable and slug-

1.

Check the welding cable con-

1. Perform the Output Rectifier

gish.

 

 

nections for loose or faulty con-

Bridge Test.

 

 

 

 

nections.

 

 

 

 

 

 

2. The control board may be faulty.

 

 

2. Make sure the wire feed speed,

Replace.

 

 

 

 

voltage, and shielding gas are

 

 

 

 

 

correct for the process being

 

 

 

 

 

used.

 

 

 

 

 

 

The arc striking is poor.

1.

Check the welding cable con-

1. The control board may be faulty.

 

 

 

nections for loose or faulty con-

Replace.

 

 

 

 

nections.

 

 

 

 

2. Make sure the wire feed speed,

 

 

 

 

 

voltage, and shielding gas are

 

 

 

 

 

correct for the process being

 

 

 

 

 

used.

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216- 383-2531 or 1-800-833-9353

WIRE-MATIC 250

Page 62
Image 62
Lincoln Electric SVM 117-A service manual Perform the Output Rectifier