Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-25

TROUBLESHOOTING & REPAIR

F-25

 

 

ABNORMAL OPEN CIRCUIT VOLTAGE

OUTPUT CAPACITOR BANK NOT FUNCTIONING

SCOPE SETTINGS

This is NOT the typical DC output voltage

 

 

waveform. The output capacitors are not

Volts/Div

.20 V/Div.

functioning. Note the lack of “filtering” in the

 

 

output waveform. The output capacitor

Horizontal Sweep

.5 ms/Div.

bank was disconnected. Each vertical divi-

 

 

sion represents 20 volts and each horizontal

Coupling

. . . . .DC.

division represents 5 milliseconds in time.

 

 

Note: Scope probes connected at machine

Trigger

. .Internal.

 

 

output terminals: (+) probe to electrode, (-)

 

 

probe to work.

 

 

 

 

 

WIRE-MATIC 250

Page 78
Image 78
Lincoln Electric SVM 117-A service manual Troubleshooting & Repair