F-3

TROUBLESHOOTING & REPAIR

F-3

 

 

 

TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE AREAS OF

 

 

RECOMMENDED

(SYMPTOMS)

 

 

MISADJUSTMENTS(S)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Major Physical or Electrical Damage

1.

Contact

your

local Lincoln

1.

Contact

The Lincoln Electric

 

is Evident

 

 

Electric

Authorized

Field

 

Service Dept. (216) 383-2531 or

 

 

 

 

Service Facility.

 

 

 

1-800-833-9353 (WELD)

 

 

 

 

 

 

Machine is dead- No Open Circuit

1.

Make certain that the input

1. Check input power switch (S1).

 

Voltage output and No Wire Feed

 

power switch is in the "ON" posi-

 

It may be faulty.

 

when gun trigger is pulled.

 

 

tion.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Check for lose or broken wires

 

 

 

2. Check the input voltage at the

 

at the reconnect panel.

 

 

 

 

machine.

Input

voltage

must

 

 

 

 

 

 

 

match the rating plate and the

3.

Perform

Main Transformer

 

 

 

 

reconnect panel.

 

 

 

Test.

 

 

 

 

3.

Blown or missing fuses in the

4. Check

the thermostats and

 

 

 

 

input line.

 

 

 

 

associated leads for loose or

 

 

 

 

 

 

 

 

 

broken connections. See wiring

 

 

 

4.

The thermostats may be open

 

diagram.

 

 

 

 

due to machine overheating. If

 

 

 

 

 

 

 

machine operates normally after

5. The control board may be faulty.

 

 

 

 

a cooling off period then check

 

Replace.

 

 

 

 

for proper fan operation and

 

 

 

 

 

 

 

ventilation. Make certain that

 

 

 

 

 

 

 

the machine's duty cycle is not

 

 

 

 

 

 

 

being exceeded.

 

 

 

 

 

 

 

 

5. Check the trigger circuit. Leads

 

 

 

 

 

 

 

#324 to #325 should have conti-

 

 

 

 

 

 

 

nuity (zero ohms) when the gun

 

 

 

 

 

 

 

trigger is pulled. If not then the

 

 

 

 

 

 

 

gun may be faulty - replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216- 383-2531 or 1-800-833-9353