Lincoln Electric SVM 117-A service manual Typical Output Voltage Waveform Machine Loaded

Models: SVM 117-A

1 102
Download 102 pages 32.42 Kb
Page 76
Image 76

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-23

TROUBLESHOOTING & REPAIR

F-23

 

 

TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED

MACHINE LOADED TO 250 AMPS AT 26 VDC

SCOPE SETTINGS

This is a typical DC output voltage wave-

 

 

form generated from a properly operating

Volts/Div

.20 V/Div.

machine. Note that each vertical division

 

 

represents 20 volts and that each horizontal

Horizontal Sweep

.5 ms/Div.

division represents 5 milliseconds in time.

 

 

The machine was loaded with a resistance

Coupling

. . . . .DC.

grid bank.

 

 

Note: Scope probes connected at machine

Trigger

. .Internal.

 

 

output terminals: (+) probe to electrode, (-)

 

 

probe to work.

 

 

 

 

 

WIRE-MATIC 250

Page 76
Image 76
Lincoln Electric SVM 117-A service manual Typical Output Voltage Waveform Machine Loaded