Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-24

TROUBLESHOOTING & REPAIR

F-24

 

 

ABNORMAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED

ONE OUTPUT SCR NOT FUNCTIONING

MACHINE LOADED TO 220 AMPS AT 22 VDC

SCOPE SETTINGS

This is NOT a typical DC output voltage

 

 

waveform. One output SCR is not function-

Volts/Div

.20 V/Div.

ing. Note the increased ripple content. One

 

 

SCR gate was disconnected to simulate an

Horizontal Sweep

.5 ms/Div.

open or non-functioning output SCR. Each

 

 

vertical division represents 20 volts and

Coupling

. . . . .DC.

each horizontal division represents 5 mil-

 

 

liseconds in time. The machine was loaded

Trigger

. .Internal.

with a resistance grid bank.

 

 

Note: Scope probes connected at machine

 

 

output terminals: (+) probe to electrode, (-)

 

 

probe to work.

 

 

 

 

 

WIRE-MATIC 255

Page 75
Image 75
Lincoln Electric SVM 119-A service manual Machine Loaded to 220 Amps AT 22 VDC Scope Settings