To mount a 10 to 44 lb. (4.5 to 20 kg) spools: 8” (200mm) [Use K468 Adapter] and 12” (300mm) diameter:

1.Remove the locking collar and the Readi-Reel Adapter (if installed) on the 2 inch (51mm) diame- ter spindle.

2.If using an 8” (200mm) spool, place the K468 Adapter on the spindle first. The hole in the Adapter arm is to engage the pin on the spindle.

3.Place the spool on the spindle, making certain the brake driving pin enters one of the holes in the back side of the spool. Be certain the wire comes off the reel in a clockwise direction when dereeled from the top of the coil.

4.Replace and tighten the locking collar for several seconds.

FEEDING ELECTRODE

WARNING

When inching, the electrode and drive mechanism are electrically hot to work and ground. The elec- trode remains hot several seconds after the gun trigger is released.

____________________________________

NOTE: Check that the proper drive rolls and gun parts for the wire size and type are being used.

1.Turn the Readi-Reel or spool until the free end of the electrode is accessible.

2.Tightly holding the electrode, cut off the bent end and straighten the first six inches.

a.If the electrode is not properly straightened, it may not feed properly into the outgoing guide tube or welding gun causing a "birdnest.")

5.Press the gun trigger and push the electrode into the drive roll.

a.If the electrode fails to thread itself into the out- going guide tube of the wire drive

open the quick release idle roll arm

thread the electrode manually

re-close the arm.

6.Inch the electrode through the gun.

NOTE: If using the low speed starting feature, the wire will feed at low speed for 2 seconds while inching, then come up to the set speed. To change run-in mode, see the Changing the Run In Mode Section.

PROPER WIRE FEEDING

Wire feeding problems can be avoided by observing the following gun handling procedures:

Do not kink or pull cable around sharp corners.

Keep the electrode cable as straight as possible when welding or loading electrode through cable.

Do not allow dolly wheels or trucks to run over cables.

Keep cable clean by following maintenance instructions.

Use only clean, rust-free electrode. The Lincoln electrodes have proper surface lubrication.

Replace contact tip when the arc starts to become unstable or the contact tip end is fused or deformed.

Return to Section TOC

Return to Master TOC

3.Cut off the first inch.

4.Push the wire through the ingoing guide tube.