Lincoln Electric SVM 119-A service manual Main Transformer Test Test Procedure

Models: SVM 119-A

1 98
Download 98 pages 51.66 Kb
Page 62
Image 62

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-11

TROUBLESHOOTING & REPAIR

F-11

 

 

MAIN TRANSFORMER TEST

TEST PROCEDURE

WARNING

The ON/OFF POWER SWITCH will be "hot" during these tests.

__________________________

NOTE: Secondary voltages will vary proportionably with the primary input voltage.

1.Disconnect the main input power supply to the machine.

2.Remove the Case Top and Side Panels with a 5/16" nut driver.

3.Locate Plug J3 and Plug J6 on the G2803 Control PC Board.

NOTE: The location of Plugs may vary depending on the machine code.

 

 

 

#202

 

 

 

 

(1J3)

 

CONTROL255 G2803

 

J3

 

 

 

 

#204A (2J3)

 

 

 

 

 

 

 

 

#203

 

 

 

 

(3J3)

 

-

 

 

#206

 

WM

 

J9

 

 

(4J6)

#209

 

 

 

 

 

 

 

 

(7J6)

 

 

 

 

J6

 

 

J4

 

#208

 

 

 

 

 

 

 

 

(16J6)

 

 

 

J5

 

J1

J7

J10

 

 

 

 

 

 

 

 

J2

 

 

FIGURE F.1 - G2803 Control PC

Board Main Transformer Test Points.

WIRE-MATIC 255

Page 62
Image 62
Lincoln Electric SVM 119-A Main Transformer Test Test Procedure, ON/OFF Power Switch will be hot during these tests