TROUBLESHOOTING & REPAIR

F-12

 

 

MAIN TRANSFORMER TEST (CONTINUED)

Return to Section

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master

Return to Master TOC

Return to Master TOC

Return to Master TOC

4.Locate the following leads on Plug J3:

G2803:

LEAD

PLUG

 

LOCATION

 

 

#202

1J3

#203

3J3

#204 A

2J3

 

 

5.Connect main input power to the machine.

6.Turn the Wire-Matic 255 ON/OFF POWER SWITCH to ON.

7.Make the following voltage tests at Plug J3.

a.Turn the machine OFF between each test.

b.Carefully insert the meter probes into the back of each Molex Plug pin cavity to perform the test.

G2803:

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

#202

#203

30 VAC

(1J3)

(3J3)

 

#202

#204 A

15 VAC

(1J3)

(2J3)

 

#203

#204 A

15 VAC

(3J3)

(2J3)

 

 

 

 

8.Turn OFF the machine

9.Locate the following leads on Plug J6 on the G2803 Control PC Board. G2803:

LEAD

PLUG

 

LOCATION

 

 

#206

4J6

#208

16J6

#209

7J6

 

 

10.Turn ON the machine.

11.Make the following voltage tests at Plug J6 on the G2803 Control PC

Board.

a.Turn the machine OFF between each test.

b.Carefully insert the meter probes into the back of each Molex Plug pin cavity to perform the test.

G2803:

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

#208

#209

60 VAC

(16J6)

(7J6)

 

#208

#206

30 VAC

(16J6)

(4J6)

 

#209

#206

30 VAC

(7J6)

(4J6)

 

 

 

 

c.If any of the voltages tested are incorrect, check for loose or bro- ken leads between the test points and the main transformer.

d.If ALL the voltages tested are incorrect or missing, go to Step 12.

12.Test for correct nameplate input volt- age between the H1 lead at the ON/OFF POWER SWITCH to H2 or H3 (H5 if connected for 575 VAC) at the reconnect panel. Voltage tested will vary depending on Input Voltage Connection. See wiring diagram for test point locations.

a.If the voltage test is incorrect,

-check for loose or broken leads between the reconnect panel and the ON/OFF POWER SWITCH.

-test the ON/OFF POWER SWITCH for proper operation.

b.If the correct nameplate voltage is being applied to the main transformer and one or more of the secondary voltages are missing or are incorrect, the main transformer may be faulty. Replace.

WIRE-MATIC 255