Read entire Installation Section before installing the WIRE-MATIC 255

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

• Only qualified personnel should install this machine.

Turn the input power OFF at the dis- connect switch or fuse box before working on the equipment.

Do not touch electrically hot parts.

Always connect the WIRE-MATIC 255 ground- ing terminal to a good electrical earth ground through the cable plug per the National Electrical Code.

Set the Wire-Matic 255 ON/OFF Power switch to the OFF position when connecting power cord to input power.

____________________________________

SELECT PROPER LOCATION

Place the WIRE-MATIC 255 where clean, cooling air can freely circulate in through the case back louvers and out through the case front louvers. Dirt, dust, or any foreign material that can be drawn into the machine case back louvers should be kept at a mini- mum. Not following these precautions can result in the nuisance shutdown of the machine because of exces- sive operating temperatures.

INPUT CONNECTIONS

WARNING

All input power must be electrically disconnected before proceeding.

____________________________________

1.Before starting the installation, check with the local power company to determine if there is any ques- tion about whether your power supply is adequate for the voltage, amperes, phase, and frequency specified on the welder nameplate. Be sure the planned installation will meet the U.S. National Electrical Code and local code requirements. This welder may be operated from a single phase line or from one phase of a two or three phase line.

2.Models that have multiple input voltages specified on the nameplate (e.g., 208/230) are shipped con- nected for the highest voltage. If the welder is to be operated at a lower voltage, it must be recon- nected according to the instructions on the inside of the removable panel (Reconnect Access Door) near the top left side of the Case Back Assembly. See the Reconnect Section of this manual for details on reconnecting the machine to operate at different voltages.

3.Be sure the voltage, phase, and frequency of the input power is as specified on the machine rating plate. See Figure A.1 for the location of the machine's input cord entry, Reconnect Access Door, and Reconnect Panel, and Rear Nameplate.

Return to Section TOC

Return to Master TOC

STACKING

The WIRE-MATIC 255 cannot be stacked.

TILTING

The Wire-Matic 255 must be placed on a stable, level surface so it will not topple over. Do not place the machine on an incline.