Lincoln Electric SVM 119-A service manual GUN Handle Disassembly, To open up the handle

Models: SVM 119-A

1 98
Download 98 pages 51.66 Kb
Page 40
Image 40

D-5

MAINTENANCE

D-5

 

 

Return to Section TOC

to Section TOC

12 Remove any burrs from the end of the liner.

13.Screw the gas diffuser onto the end of the gun tube and tighten.

NOTE: Be sure the gas diffuser is correct for the liner being used. (See table and diffuser stencil.)

14.Slightly tighten the set screw in the side of the gas diffuser against the cable liner using 5/64" (2.0mm) Allen wrench.

CAUTION

This screw should only be gently tightened. Over tightening will split or collapse the liner and cause poor wire feeding.

____________________________________

COUNTER-

CLOCKWISE

FIGURE D.3 - Gun Handle disassembly.

Return

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

GUN HANDLE DISASSEMBLY

The internal parts of the gun handle may be inspected or serviced if necessary.

The gun handle consists of two halves that are held together with a collar on each end.

To open up the handle:

1.Turn the collars approximately 60 degrees coun- terclockwise (the same direction as removing a right hand thread) until the collar reaches a stop.

2.Pull the collar off the gun handle.

NOTE: If the collars are difficult to turn, position the gun handle against a corner, place a screwdriver against the tab on the collar and give the screwdriver a sharp blow to turn the collar past an internal locking rib. See Figure D.3.

WIRE-MATIC 255

Page 40
Image 40
Lincoln Electric SVM 119-A service manual GUN Handle Disassembly, To open up the handle