F-25

TROUBLESHOOTING & REPAIR

F-25

 

 

ABNORMAL OPEN CIRCUIT VOLTAGE

OUTPUT CAPACITOR BANK NOT FUNCTIONING

SCOPE SETTINGS

This is NOT the typical DC output voltage

 

 

waveform. The output capacitors are not

Volts/Div

.20 V/Div.

functioning. Note the lack of “filtering” in the

 

 

output waveform. The output capacitor

Horizontal Sweep

.5 ms/Div.

bank was disconnected. Each vertical divi-

 

 

sion represents 20 volts and each horizontal

Coupling

. . . . .DC.

division represents 5 milliseconds in time.

 

 

Note: Scope probes connected at machine

Trigger

. .Internal.

 

 

output terminals: (+) probe to electrode, (-)

 

 

probe to work.

 

 

 

 

 

WIRE-MATIC 255