Connecting Devices to the SGE2010/SGE2010P

Placement Options

CAUTION: Keep enough ventilation space for the Ethernet switch so it does not exceed the environmental restrictions mentioned in the specifications.

Rack-Mount Placement

To mount the Ethernet switch in any standard-sized, 19-inch wide, (each Ethernet switch requires 1RU of space in the rack), follow these instructions:

1.Remove the four front screws on one side of the Ethernet switch. Retain the screws for re- installation.

2.Place one of the supplied spacers on the side of the Ethernet switch so the four holes align to the screw holes.

3.Place a rack mount bracket next to the spacer and reinstall the four screws (removed in step 1).

4.Repeat steps 2 through 3 for the other side of the Ethernet switch.

5.Attach the Ethernet switch to the rack using the supplied screws.