Using the Main Menu

 

 

 

 

Alarm Input & Output Menu2. Click to assign an Event notification

 

 

(Motion, VLoss, Alarm, HDD ON/OFF) to an

 

 

 

 

Alarm-Out notification (Buzzer, Alarm

 

 

Full-Screen, Label, Alarm Out 1).

Figure 13.0b Alarm Input & Output menu

Alarm-InType:SelectNO(normallyopen) or NC (normally closed) for the alarm in device.

VLoss Response Time: Select the time (in seconds) for the system to record prior to a triggered event: 0, 3, 5, 10, 30, 60, 120, 180, or Infinite.

Response Duration: Select the time (in seconds) for the system to record after a triggered alarm or motion event: 1~255.

NOTE: The Response Duration also applies to the accompanying message and/or buzzer.

Alarm-In Setup Menu

Buzzer: Select O to enable the system to beep when an alarm is triggered or motion is detected; select X to disable it.

Alarm Full Screen: Select O to enable a full-screen display of the active alarm/motion channel; select X to disable it.

Label: Select O to enable the system to display camera OSD when an alarm triggers.

Alarm Out 1: Alarm 1 output.

3.To save your settings, right-click until you return to the main screen.

Figure 13.0c Alarm-In Setup menu

To configure the Alarm-In Setup:1.Click Alarm-In Setup.

2.Click on the desired alarm number (alarm 1~4) and assign it to the desired camera number.

Alarm-Out Setup Menu

Figure 13.0d Alarm-Out Setup menu

To configure the Alarm-Out Setup menu:1.Click Alarm-Out Setup.