Appendix - Fault Isolation
CABLE
CABPCU
CABPSU
CABPWR
CABTMP
CABTMP
CDCREG
CHARGE
DSKFAN
ENC OK
ENCFLT
FIBER
FIBER
HARD
HWFLT
ILLBRK
INVREG
IPS OK
IPSFlt
IS
LITEOK
MISSNG
![]()
PCI Power Cable Missing
Cabinet Power Control Unit Fault
Cabinet Power Supply Unit Fault
Broken Cabinet Power
Controller
Cabinet Battery Temperature Fault
![]()
Cabinet Temperature Fault ![]()
Cabinet Data Registers Invalid
Charging Battery
![]()
Disk Fan Faulted/Missing ![]()
SCSI Peripheral Enclosure OK
SCSI Peripheral Enclosure Fault
![]()
Cabinet ![]()
Cabinet
Hard Error
![]()
Hardware Fault
![]()
Cabinet Illegal Breaker Status
Invalid ACU Register
Information
IOA Chassis Power Supply
OK
IOA Chassis Power Supply Fault
![]()
In Service
![]()
Cabinet Fault Light OK
![]()
Missing replaceable unit
![]()
This PCI backpanel cable is not attached.
![]()
A power control unit faulted.
![]()
A power supply unit faulted.
![]()
A cabinet power controller failed.
A cabinet battery temperature above the safety threshold was detected.
A cabinet temperature above the safety threshold was detected.
The cabinet data collector is returning incorrect register information. Upgrade the unit.
A battery CRU/FRU is charging. To leave this state, the battery needs to be permanently bad or fully charged.
![]()
The disk fan either faulted or is missing.
![]()
The SCSI peripheral enclosure is OK.
![]()
A device in the tape/disk enclosure faulted.
![]()
The cabinet ![]()
The cabinet
The driver reported a hard error. A hard error occurs when a hardware fault occurs that the system is unable to correct. Look at the syslog for related error messages.
The hardware device reported a fault. Look at the syslog for related error messages.
The cabinet data collector reported an invalid breaker status.
A read of the ACU registers resulted in invalid data.
![]()
The IOA chassis power supply is OK.
![]()
An I/O Adapter power supply fault was detected.
![]()
The CRU/FRU is in service. ![]()
The cabinet fault light is OK.
The ACU on the DNCP Series