Manitowoc Ice service manual Section Electrical System, S1800 SELF-CONTAINED 3 Phase

Models: S1800

1 100
Download 100 pages 24.15 Kb
Page 49
Image 49

Section 6

Electrical System

 

 

S1800 - SELF-CONTAINED - 3 PHASE

L3 L2 L1

(89)(55)

HIGH PRESSURE

CUTOUT

(88)

(42)

ICE THICKNESS

PROBE

WATER

VALVE

(20)(21)

 

 

 

 

(22)

 

 

 

LH HARVEST

 

 

 

SOLENOID

 

 

(61)

(77)

 

 

 

 

 

(87)

CONTROL BOARD

 

(88)

(99)

 

 

 

(2)

 

 

 

 

(6)

 

(60)

RH HARVEST

(80)

(5)

 

 

SOLENOID

 

 

 

 

 

(1)

 

 

(76)

(81)

(7)

 

 

DUMP

(4)

 

(57)

SOLENOID

 

 

 

(98)

 

 

 

 

 

TRANS.

 

 

 

WATER

 

 

 

PUMP

 

 

 

 

FUSE (7A)

 

(58)

TERMINATES AT

 

 

 

 

 

 

PIN CONNECTION

 

 

 

(59)

 

CLEAN

L2

AIR

CONTACTOR

 

LEFT BIN

 

 

COMP

 

RIGHT BIN

 

(56)

COIL

 

RMT BIN

 

 

 

 

WTR PROBE

 

(26)

AIR

 

ICE PROBE

 

(75)

 

 

COMPRESSOR

HARV

 

 

WHEN USED

 

SL-1

 

(25)

 

 

SL-2

(9)

 

 

 

 

 

L3 L2 L1

WATER LEVEL

PROBE

CONTACTOR

LOW D.C.

VOLTAGE PLUG

(8)

 

BIN

(74)

(6)

SWITCH

 

 

 

(1)

CLEAN

OFF

 

 

ICE

(2)

 

T2

T3 T1

COMPRESSOR

CONTACTS

(51)

FAN MOTOR

(AIR COOLED ONLY)

(85)(86)

FAN CYCLE CONTROL

RUN CAPACITOR**

Part Number 80-1634-3

6-11

Page 49
Image 49
Manitowoc Ice service manual Section Electrical System, S1800 SELF-CONTAINED 3 Phase