Section 6 | Electrical System |
|
|
ICE/OFF/CLEAN TOGGLE SWITCH
Function
The switch is used to place the ice machine in ICE, OFF or CLEAN mode of operation.
Specifications
Check Procedure
NOTE: Because of a wide variation in D.C. voltage, it is not recommended that a volt meter be used to check toggle switch operation.
1.Inspect the toggle switch for correct wiring.
2.Isolate the toggle switch by disconnecting the Molex connector.
3.Check continuity across the toggle switch terminals. Note where the wire numbers are connected to the switch terminals, or refer to the wiring diagram to take proper readings.
Switch Setting | Terminals | Ohm Reading |
| Open | |
ICE | Closed | |
| Open | |
| Closed | |
CLEAN | Open | |
| Open | |
| Open | |
OFF | Open | |
| Open |
4.Replace the toggle switch if ohm readings do not match all three switch settings.
Part Number |