INSTALLATION/VISUAL INSPECTION CHECKLIST

Possible Problem

Corrective Action

Ice machine is not level

Level the ice machine

Condenser is dirty

Clean the condenser

Water filtration is plugged (if

Install a new water filter

used)

 

Water drains are not run

Run and vent drains

separately and/or are not

according to the Installation

vented

Manual

Line set is improperly

Reinstall according to the

installed

Installation Manual

WATER SYSTEM CHECKLIST

A water-related problem often causes the same symptoms as a refrigeration system component malfunction.

Water system problems must be identified and eliminated prior to replacing refrigeration components.

Possible Problem

Corrective Action

Water area (evaporator) is

Clean as needed

dirty

 

Water inlet pressure not

Install a water regulator valve

between 20 and 80 psi

or increase the water

(1-5 Bar, 138- 552 kPa)

pressure

Incoming water temperature

If too hot, check the hot water

is not between 35°F (1.6°C)

line check valves in other

and 90°F (32.2°C).

store equipment

Water filtration is plugged (if

Install a new water filter

used)

 

Water dump valve leaking

Clean/replace dump valve as

during the freeze cycle

needed

Vent tube is not installed on

See Installation Instructions

water outlet drain

 

Hoses, fittings, etc., are

Repair/replace as needed

leaking water

 

Water fill valve is stuck open

Clean/replace as needed

Water is spraying out of the

Stop the water spray

sump trough area

 

Uneven water flow across the

Clean the ice machine

evaporator

 

Water is freezing behind the

Correct the water flow

evaporator

 

Plastic extrusions and

Remount/replace as needed

gaskets are not secured to

 

the evaporator

 